Shopfront detail on Motcomb Street
No. 2 is the shopfront the schedule can describe in parts. An arched central display window sits between a shop doorway and a house doorway, and both doorways have square-headed fanlights. The arch, the shop opening, the house opening and the fanlights are the detail decoration must keep. Paint is not a reason to ease an arch into a flatter curve, to lose the square head of a fanlight, or to bridge the stile and the stucco with a heavy film until the joint disappears. The stucco of the shopfront and the joinery set in it are itemised apart, even when they will be similar in colour.
No. 1 is a corner. A mid-19th-century Grade II corner shopfront has a front and a return meeting at the turn, and a quotation that draws only the face the painter happens to be looking at has missed the return. Returns, the corner pier and both runs of glazing are recorded. The Halkin Arcade is purpose-built commercial fabric from the original development, grouped by the audit with the Pantechnicon. Its shopfronts are read as arcade fronts, with their own openings and their own joinery, not as a terrace of house bays that happen to have glass in them. Each unit in the instruction is named.
Consent where the shopfront is listed
No. 1 and No. 2 are Grade II. Like-for-like external redecoration, matching paint type, texture, finish and colour, usually does not need listed building consent. A further coat on the stucco arch and on joinery that is already painted in that same system sits in that advice. A change of type, texture, finish or colour does not. Changing a fanlight from a square head, blocking a light, or simplifying the stucco arch is not redecoration at all. The commercial instruction should say, in writing, whether the work is a match. If it is not, consent is resolved before the coating is applied.
A shared stair in a block of flats is a different instruction from these shopfronts, and it should not be folded into the shopfront consent note. Where the work really is a common stair or other circulation space in a block of flats, linings are chosen to a minimum class of B-s3, d2. That class is not a shopfront paint system, and it is not assumed for No. 1 or No. 2. If the premises have no common stair in the instruction, the lining class is left out of the quotation rather than copied onto a display window. The site visit is what decides whether a stair is even in scope.
Surfaces in a commercial schedule
The surfaces are the stucco of the shopfront, the joinery of doors, frames and fanlights, the glazing that must be protected, and the wall above the shopfront where that wall is actually included. No. 2's stucco arch is a modelled stucco surface. The square-headed fanlights are joinery around glass. Treating them as one substrate produces the wrong preparation and the wrong coating. The corner at No. 1 adds the return face. Purpose-built fronts at the Halkin Arcade and the Pantechnicon are scheduled as the commercial buildings they are, opening by opening, rather than as a single palace wall.
Windsor-style lamp standards stand on Motcomb Street and the audit treats them as part of the street's character. They are not a decorating surface for a shopfront recoat. They are not resprayed, stripped or used as a colour sample for the joinery unless a separate instruction says so. Glass, cills and any stall board under a display window are protected from preparation and from drips. Door leaves and fanlight sashes stay able to move. Colour is sampled on stucco and on joinery separately, because a match that looks right on a flat stile can look wrong on the arch.
Preparation of joinery and stucco
Failed coatings are recorded against damaged render or damaged timber before anyone decides how much material comes off. Sound paint on the stucco arch is not stripped because a neighbouring stile is flaking. The joinery is prepared to a joinery system, cut in to the stucco, and the stucco is prepared to a masonry coating where that is what the existing face requires. The square-headed fanlights are delicate: preparation does not round their bars or glue them shut. Glazing is masked before rubbing down starts beside it.
The corner shopfront at No. 1 is prepared on both faces, including the piece of joinery or stucco that turns the corner, which is where coatings usually fail first. Arcade fronts are prepared unit by unit so that a closed shop is not assumed to be the same condition as an open one. Colour samples are set on the real surfaces and left to be read in daylight. Moving parts, including both doorways at No. 2, are eased and left free. Nothing in the record of the fire in February 1874, or of the 1830 design, tells the painter which of today's coatings is loose. Only the visit does that.
Access beside a working shop
These are purpose-built commercial buildings, and the ground floor is how the building trades. A display window, a shop door and a house door at No. 2 may all need to stay in use while decoration goes on. The plan says which opening can be closed, which must work at the end of the session, and how customers and residents pass the work. Protection covers glass, thresholds and stock near the glass. Materials are not stood in the only doorway. A corner site at No. 1 has to be thought about from each street it fronts.
If a scaffold is the way to reach the front above the shopfront, and that scaffold stands on the footway, a Westminster pavement licence is required. This page gives no cost for the licence. The licence is an access item beside the decorating scope, not a substitute for it. Upper stucco, a fascia or an arcade opening is not reached by leaning a board on the shopfront. The quotation names the access method after the visit, because a corner, an arcade and a single shop door do not share one arrangement.
Cost factors for these shopfronts
Cost turns on the detail and the condition, and no figure is stated here. An arched stucco shopfront with a shop doorway, a house doorway and square-headed fanlights is a more exacting item than a plain door in a flat wall. A corner brings the return into the same scope. Arcade units multiply the openings. Loose coatings and damaged render or timber add preparation that a sound surface does not need. Separating joinery from the wall above adds lines, and it also stops the mistake of a single coating everywhere. Protection of glazing and of a trading floor is a factor.
Consent is a factor when the instruction is not like-for-like. A match of type, texture, finish and colour is a different scope from a new colour or a new sheen on a Grade II front. Access is a factor when the footway must take a scaffold and a pavement licence has to be in place. A common stair, if one is truly in the instruction, brings its own lining requirement of B-s3, d2, which is not specified as if it were the shopfront. Windsor-style lamps stay out of the cost unless they are separately instructed. Samples and making good to moving parts sit in the same list. Still no figure.
A written itemised quotation after the site visit
The quotation is written after the shopfront has been seen. The visit identifies whether the instruction is No. 2, No. 1, a unit in the Halkin Arcade, a remaining commercial front of the Pantechnicon, or some combination. It notes the arch, the fanlights, the corner, the condition of the coatings and whether any common stair is actually included. It does not treat February 1874 or the 1830 design as a specification. It does not add the Windsor-style lamp standards. It separates the wall above from the shopfront joinery.
Itemised lines cover preparation, joinery coatings, stucco coatings, repairs where render or timber is damaged, protection of glazing and stock, and access, including a pavement licence where a scaffold will stand on the footway. If a shared stair in a block of flats is in scope, the lining class B-s3, d2 is stated on that line alone. Exclusions are plain: lamps left alone, openings not in the instruction, and any change of type, texture, finish or colour that has not been resolved as a consent matter. The figure comes from that visit, not from this page.
Sources
Questions about this decorating work
How should the Grade II shopfront at No. 2 be decorated?
No. 2 is a simple stucco shopfront. An arched central display window is flanked by a shop doorway and a house doorway, each with a square-headed fanlight. Those parts are the schedule. The stucco arch is prepared and coated as stucco. The doorways and fanlights are joinery, kept separate from the wall above, with glazing protected and moving parts left free. Decoration does not flatten the arch or lose the square heads. Like-for-like redecoration, matching paint type, texture, finish and colour, usually does not need listed building consent. A change of any of those is a different instruction and is settled first.
Should the Windsor-style lamps be resprayed with the shops?
No. Traditional Windsor-style lamp standards on Motcomb Street are street furniture, and the audit treats them as part of the character of the street. They are not a stallriser, a fascia or a shopfront stile. A shopfront quotation does not include stripping or recoating them unless a separate instruction names the lamps. The decorating surfaces are the commercial fronts: No. 1 as a mid-19th-century corner shopfront, No. 2 with its stucco arch and fanlights, and the purpose-built Halkin Arcade and Pantechnicon where those buildings are in the instruction. Colour samples belong on those fronts, not on the lamps.
When does the lining class B-s3, d2 apply on this street?
Only when the instruction includes a circulation space in a block of flats, such as a common stair. The minimum lining classification for those common areas is B-s3, d2. It governs coatings and wallcoverings on that stair. It does not govern the stucco arch at No. 2, the corner shopfront at No. 1, or a display window in the Halkin Arcade. Those are shopfronts, specified for their own substrates, with listed like-for-like rules where the front is Grade II. If the visit finds no common stair in scope, the class is omitted rather than written onto the shopfront by habit.
Read next
- Motcomb Street and the Pantechnicon stucco front in London. The street page names the purpose-built commercial buildings the shopfront work sits on.
- Stucco painting for Motcomb Street shopfronts in London. Exterior painting on the same street deals with the stucco wall and the column screen as their own scope.
- Commercial decorating. The commercial service is the wider brief for premises that stay in use while they are decorated.
- Shopfront decorating along Elizabeth Street in London. Elizabeth Street is a separate shopfront schedule, with its own entablatures and brackets.
Once the arch, the fanlights, the corner and any stair in scope have been seen, ask for a written Motcomb Street shopfront quotation. The reply should itemise joinery, stucco, protection and access, and leave street lamps out unless they were instructed.